{"id":29242,"date":"2026-05-19T09:24:09","date_gmt":"2026-05-19T09:24:09","guid":{"rendered":"https:\/\/eyelidophthalmic.us.com\/?page_id=29242"},"modified":"2026-05-20T04:44:56","modified_gmt":"2026-05-20T04:44:56","slug":"preloaded-aspheric-hyrdrophobic","status":"publish","type":"page","link":"https:\/\/eyelidophthalmic.us.com\/?page_id=29242","title":{"rendered":"PRELOADED ASPHERIC HYRDROPHOBIC"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Preloaded <\/p>\n\n\n\n<div class=\"wp-block-group alignfull is-style-ext-preset--group--natural-1--section has-background-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0;padding-top:var(--wp--preset--spacing--70);padding-bottom:var(--wp--preset--spacing--70)\">\n<div class=\"wp-block-group alignwide ext-is-logical-start is-content-justification-left is-layout-constrained wp-container-core-group-is-layout-1b5539f4 wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-left ext-animate--on\">Eyelid monofocal IOL Offers<\/h2>\n\n\n\n<p class=\"has-text-align-left ext-animate--on wp-block-paragraph\" style=\"margin-top:1.5rem\">Eyelid monofocal IOL optical design offers an advanced vision, especially when the pupil becomes larger in the dim light condition; the posterior surface is the higher order aspherical surface, which aims to compensate the different corneal aberration and realize the higher contrast sensitivity and different depth of focus to meet the vision needs from different patients.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-stretch ext-animate--on is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group is-style-ext-preset--group--natural-1--item-card-1--align-start has-tertiary-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-eea54bf5 wp-block-group-is-layout-flex\" style=\"min-height:100%;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-group is-style-default wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-d0b6506f wp-block-group-is-layout-flex\" style=\"margin-top:0;padding-top:1.5rem;padding-right:1.5rem;padding-bottom:1.5rem;padding-left:1.5rem\">\n<div class=\"wp-block-columns is-not-stacked-on-mobile is-layout-flex wp-container-core-columns-is-layout-5556964c wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading has-medium-font-size\">Hydrophobic Aspheric<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:4px;margin-bottom:0;font-size:14px\">2.&nbsp; Eyelid &nbsp;monotonal IOLs&nbsp;offer slight negative asphericity that neutralizes part of the positive aberration of the cornea.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a3c9b07e\">4. Eyelid &nbsp;IOLs has sharp square edge which effectively prevents PCO<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:4px;margin-bottom:0;font-size:14px\">5. Eyelid Natural Yellow IOL protect the macula against UV and partial blue light, preserving natural color perception and contrast sensitivity under mesopic conditions<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-stretch ext-animate--on is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group is-style-ext-preset--group--natural-1--item-card-1--align-start has-tertiary-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-eea54bf5 wp-block-group-is-layout-flex\" style=\"min-height:100%;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-group is-style-default wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-d0b6506f wp-block-group-is-layout-flex\" style=\"margin-top:0;padding-top:1.5rem;padding-right:1.5rem;padding-bottom:1.5rem;padding-left:1.5rem\">\n<div class=\"wp-block-wd-container wd-dir-col wd-87cbb22b\"><\/div>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4c95974b\">PRELOADED ASPHERIC<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>MODEL<\/strong><\/td><td><strong>PML26<\/strong>, PML 28<\/td><\/tr><tr><td><strong>Lens Type<\/strong><\/td><td><strong>Single-piece Posterior Chamber lOL<\/strong><\/td><\/tr><tr><td><strong>Optic Design<\/strong><\/td><td><strong>Monofocal, Aspherical Posterior Surface, Biconvex, Aberration-free<\/strong><\/td><\/tr><tr><td><strong>Material<\/strong><\/td><td><strong>Biocompatible Hydrophobic Acrylate Copolymer,<\/strong> <strong>Blocking UV and Partial Blue Light<\/strong> <strong>Water content:&lt;0.5%<\/strong><\/td><\/tr><tr><td><strong>Color<\/strong><\/td><td><strong>Slightly Yellow<\/strong><\/td><\/tr><tr><td><strong>Refractive Index<\/strong><\/td><td><strong>1.55 at 35\u00b0C<\/strong><\/td><\/tr><tr><td><strong>Diopter Range<\/strong><\/td><td><strong>+10.0 D ~ +30.0 D (0.5D increment)<\/strong><\/td><\/tr><tr><td><strong>Haptic Confguration<\/strong><\/td><td><strong>Modifed C-Loop, 0\u00b0angulation<\/strong><\/td><\/tr><tr><td><strong>Diameters<\/strong><\/td><td><strong>6.0 mm ( Effective Optical Diameter ) \/ 13.0 mm ( Overall length )<\/strong><\/td><\/tr><tr><td><strong>Edge Design<\/strong><\/td><td><strong>Sharp Square Edge<\/strong><\/td><\/tr><tr><td><strong>Recommended Optical .A Constant<\/strong><\/td><td><strong>119.2<\/strong><\/td><\/tr><tr><td><strong>Recommended Ultrasound .A Constant<\/strong><\/td><td><strong>118.9<\/strong><\/td><\/tr><tr><td><strong>Optimized Constants<\/strong><\/td><td><strong>Haigis: a0=-1.627, a1=0.305, a2=0.248<\/strong> <strong>Hoffer Q: pACD=5.64; Holladay I: SF=1.95;<\/strong> <strong>Holladay II: ACD=5.745; Barrett LF:1.99<\/strong><\/td><\/tr><tr><td><strong>Sterilization<\/strong><\/td><td><strong>Ethylene Oxide<\/strong><\/td><\/tr><tr><td><strong>Injector<\/strong><\/td><td><strong>Medicel ACCUJECT Dual Pro ( Push \/ Screw Mode )<\/strong><\/td><\/tr><tr><td><strong>Incision Size<\/strong><\/td><td><strong>2.2mm<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"http:\/\/eyelidophthalmic.us.com\/wp-content\/uploads\/2021\/10\/20250214173950041970.png\" alt=\"\" class=\"wp-image-29046\" style=\"width:626px;height:auto\" srcset=\"https:\/\/eyelidophthalmic.us.com\/wp-content\/uploads\/2021\/10\/20250214173950041970.png 800w, https:\/\/eyelidophthalmic.us.com\/wp-content\/uploads\/2021\/10\/20250214173950041970-300x300.png 300w, https:\/\/eyelidophthalmic.us.com\/wp-content\/uploads\/2021\/10\/20250214173950041970-150x150.png 150w, https:\/\/eyelidophthalmic.us.com\/wp-content\/uploads\/2021\/10\/20250214173950041970-768x768.png 768w, https:\/\/eyelidophthalmic.us.com\/wp-content\/uploads\/2021\/10\/20250214173950041970-430x430.png 430w, https:\/\/eyelidophthalmic.us.com\/wp-content\/uploads\/2021\/10\/20250214173950041970-700x700.png 700w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7c715c8e\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Preloaded Eyelid monofocal IOL Offers Eyelid monofocal IOL optical design offers an advanced vision, especially when the pupil becomes larger<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-29242","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/eyelidophthalmic.us.com\/index.php?rest_route=\/wp\/v2\/pages\/29242","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eyelidophthalmic.us.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/eyelidophthalmic.us.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/eyelidophthalmic.us.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/eyelidophthalmic.us.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=29242"}],"version-history":[{"count":3,"href":"https:\/\/eyelidophthalmic.us.com\/index.php?rest_route=\/wp\/v2\/pages\/29242\/revisions"}],"predecessor-version":[{"id":29263,"href":"https:\/\/eyelidophthalmic.us.com\/index.php?rest_route=\/wp\/v2\/pages\/29242\/revisions\/29263"}],"wp:attachment":[{"href":"https:\/\/eyelidophthalmic.us.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=29242"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}